T-AGHV LVMP
Comparing the existing Air Spray Gun or HVLP gun
LVMP gun makes higher transfer efficiency and better atomization possible with less air consumption.
- High Transfer Efficiency
- Fine Atomization
- Low Air Consumption
Why does LVMP have better transfer efficiency?
The difference of the transfer efficiency between standard spray gun and HVLP gun is the air velocity. The both air velocities are in the same sound-speed area when an instant of coming out from the air cap. However, when it becomes the distance of approximately 200mm, it generates large difference.
Therefore, if the velocity is low at 200mm distance, the transfer efficiency becomes better even atomized with higher air pressure than HVLP.
Gun Types | Gun Inlet Pressure | Air Cap Pressure | Air Consumption | Air Velocity | Transfer Efficiency |
---|---|---|---|---|---|
AGXV-541-5805-DFX (LVMP Gun) | 0.25MPa | 0.20MPa | 280L/min | 16m/sec. | 74% |
AGXV-541-46-FX (HVLP Gun) | 0.45MPa | 0.09MPa | 750L/min | 19m/sec. | 55% |
AGX-550-777-FX (Standard Gun) | 0.40MPa | 0.35MPa | 500L/min | 22m/sec. | 44% |
(Spray Distance=200mm)
Specifications
Atomization Air Pressure (Gun Inlet) | 0.4MPa (4.0kgf/cm²) |
---|---|
Fluid Pressure | 0.7MPa (7.0kgf/cm²) |
Working Pressure | 0.35 ~ 0.7MPa (3.5 ~ 7.0kgf/cm²) |
Weight | 510g |
Fluid Inlet | R1/8 |
Cylinder Air Inlet (CYL) | R1/8 |
Atomization Air Inlet (CAP) | R1/8 |
Pattern Air Inlet (FAN) | R1/8 |
Measurement | L92 × W40 × H40mm |
Air Cap, Fluid Tip Selection
Fluid Tip Size | Air Cap No. | ||
---|---|---|---|
805 | 807 | 805MT | |
GD (0.7mm) | ✔ | ✔ | G (0.7mm) |
DFX (1.1mm) | ✔ | ✔ | FX (1.1mm) |
DFW (1.6mm) | ✔ | ✔ | - |
Spray Pattern (Spray Distance=200mm) |
220mm (DFX) |
300mm (DFX) |
180mm (FX) |