Quick Cleaners
Cleans the inner hose and fluid passage quickly and efficiently.
Save cleaning time and reduce consumption of solvent by flushing out the paint in the fluid passage used with mixing air and solvent.
Air is mixed with the cleanser, flowing through the fluid passage at high pressure. Materials in the fluid passage are scraped off by the air bubbles in the mixed fluid, saving time.
The difference in the cleansing time
Cleaning low viscosity materials: | cleansing time |
---|---|
* Using the Quick Cleaner | 6.6 seconds |
* Using the thinner | 8.3 seconds |
Cleaning high viscosity materials: | cleansing time |
* Using the Quick Cleaner | 11.5 seconds |
* Using the thinner | 14.7 seconds |
Test Condition :
- Viscosity : 12 seconds/IHS (low viscosity), 36 seconds/IHS (high viscosity)
- Hand Spray Gun Fluid Tip Size : 1.0 mm
- Fluid hose : PTFE 6×4 mm
- Fluid hose length : 2.5 m
HD-505-W
Specifications
Cleaning Solvent Capacity | 5L |
---|---|
Air Inlet Size | G 1/4 |
Cleaning Solvent Outlet Size | G 3/8 |
Maximum Working Pressure | 0.69 MPa |
* Regulate to 0.69MPa max * Dedicated Organic Solvent |
HD-510
Specifications
Cleaning Solvent Capacity | 10L |
---|---|
Air Inlet Size | G 1/4 |
Cleaning Solvent Outlet Size | G 3/8 |
Maximum Working Pressure | 0.69 MPa |
* Regulate to 0.69MPa max * Dedicated Organic Solvent |
HD-QCH Quick Cleaner Head
Quick Cleaner head to mix solvents and compressed air
easy to refill cleaning solvent
Specifications
Specifications | R1/4(M) (with check valve:1/4Taper male screw) |
---|---|
Cleaning Solvent Inlet | G 1/4(F) |
Cleaning Solvent Outlet | R3/8(M) |
Main Body Material | SUS |
* Regulate to 0.69MPa max * For Water and Organic Solvent * All screw at Quick Cleaner Head are female straight threads |
HD-QCH-DX Quick Cleaner head pump unit
The unit includes HD-QCH and Diaphragm pump*
easy to refill cleaning solvent
*With DX70R3-T Diaphragm pump is standard model.
Please contact us for other combination.
Specifications
Air Inlet Size | R1/4(M) (with check valve:1/4Taper male screw) |
---|---|
Cleaning Solvent Inlet | G1/4(F) |
Cleaning Solvent Outlet | R3/8(M) |
Main Body Material | SUS |
* Regulate to 0.69MPa max * For Water and Organic Solvent * All screw at Quick Cleaner Head are female straight threads |
HD-505-W/HD-510 Installation Example